{"id":1135,"date":"2016-03-01T11:45:57","date_gmt":"2016-03-01T10:45:57","guid":{"rendered":"https:\/\/srcsl.com\/mantenimiento-de-sensores-en-fundicion-no-ferrica\/"},"modified":"2026-02-09T14:36:50","modified_gmt":"2026-02-09T13:36:50","slug":"maintenance-of-sensors-in-non-ferrous-casting","status":"publish","type":"post","link":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/","title":{"rendered":"How to keep temperature sensors for aluminum casting in optimal condition?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1135\" class=\"elementor elementor-1135\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1a4d1c80 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1a4d1c80\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-445f0ea7\" data-id=\"445f0ea7\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-af33f90 elementor-widget elementor-widget-heading\" data-id=\"af33f90\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">How to keep temperature sensors for aluminum casting in optimal condition?<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f03ebfe elementor-widget elementor-widget-text-editor\" data-id=\"f03ebfe\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Sensor maintenance in aluminum castings is a key task to maintain proper performance of these sensors.<\/p><p>Temperature is one of the primary variables in an aluminum casting process. It is necessary to monitor and maintain control of the temperature of the molten aluminum, since some physical properties that we seek for the final piece, such as tensile strength, can be affected in the case of having sensors with faulty maintenance.<\/p><p>It&#039;s advisable to measure the temperature in the melt itself, using thermocouples protected with special sheaths (pyrometric tubes for aluminum smelting). This will make the measurement more precise and tailored to the process we want to perform.<\/p><p>The lower scrap volume, resulting from a proper process thanks to thorough temperature control, leads to a reduction in operating costs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98cf187 elementor-widget elementor-widget-heading\" data-id=\"98cf187\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">MAINTENANCE<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3711cdd elementor-widget elementor-widget-text-editor\" data-id=\"3711cdd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In aluminum foundry, correct maintenance of the pyrometric tubes during the processes is a decisive advantage to achieve high-quality production in terms of castings. Too hot molten aluminum can damage the molds, excessively low temperature will hinder production and reduce fluidity, especially in the most demanding parts of the foundry when it comes to detailing the casting characteristics and the precision of the control.<\/p><p>A melt that does not reach the ideal heat will show insufficient metal flow into the passages of the mold and may cause bubbles or holes. The temperature also has consequences on the physical capabilities of the product to be achieved.<\/p><p>Difficulties are likely to arise during post-welding or machining. Even worse is the realization that defects cannot be identified until the final products are used and integrated with other parts. Poor temperatures will produce brittle castings, prone to wear and material fatigue.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a3aa26 elementor-widget elementor-widget-heading\" data-id=\"3a3aa26\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">CALIBRATION<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aff7688 elementor-widget elementor-widget-text-editor\" data-id=\"aff7688\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>It&#039;s a good idea to periodically calibrate temperature sensors and controllers to ensure proper measurement of all equipment. Remember that coolants can cause corrosion and impair sensor response, so take the time to properly secure the sensor bracket and place it in the correct location.<\/p><p>Isolating it from impurities is also important, since they could clog the ducts, and hinder the sensors when making the relevant readings. For this, jacketed thermocouples are used that isolate the sensor from these drawbacks.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-affb5d0 elementor-widget elementor-widget-heading\" data-id=\"affb5d0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">REPLACEMENT<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da19cb4 elementor-widget elementor-widget-text-editor\" data-id=\"da19cb4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Replace the sensor if it verifies that the specified checks are not within the limit values marked for its manufacture.<\/p><p>It is very important to have a good support for the pyrometric rods in both melting and maintenance furnaces, since if they are not properly fastened they can have sudden movements and receive blows (with ingots, against the crucible wall, etc.)<\/p><p>Our cases at room temperature can resist shock well but when immersed in aluminum at 700\u00baC they are all fragile. Before immersing them in aluminum at 700\u00baC, it is recommended to preheat them to avoid breakage due to thermal shock.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a62de46 elementor-widget elementor-widget-heading\" data-id=\"a62de46\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">INSTRUCTIONS FOR USE OF SRC COVERS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cbd1af4 elementor-widget elementor-widget-text-editor\" data-id=\"cbd1af4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Our covers are made of materials for non-ferrous casting and have excellent characteristics such as high resistance to impacts, corrosion and thermal shock. These features give these sleeves a long life in temperature measurement of molten aluminum, zinc and copper alloys.<\/p><p>The covers have an optional support with or without tilting system (anti-shock protection).<\/p><p><strong>SRC<\/strong> can supply all its models of covers mounted on pyrometric reeds tailored to the customer.<\/p><p>Once you receive our cover, proceed to inspect it. In case of breakage, contact your nearest distributor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-facce20 elementor-widget elementor-widget-heading\" data-id=\"facce20\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">INTERIOR INSTALLATION<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c0f815 elementor-widget elementor-widget-text-editor\" data-id=\"1c0f815\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>If the protective sheath is attached to a thermocouple, a space must be left between the bottom of the sheath and the thermocouple tip. There is a significant difference in the coefficient of thermal expansion between the thermocouple (NiCr-Ni: 13\u00d710-6) and the SRC sheath (3\u00d710-6).<\/p><p>The bottom of this will break when the above mentioned space is insufficient.<\/p><p><strong>Enough Space<\/strong> = Temperature x Length x (10\u00d710-6) x Safety Coefficient<br \/><strong>Example using working temperature<\/strong> 700\u00baC Length 1000 mm.<br \/><strong>Enough Space<\/strong> = 700 x 1000 x 10 x 10-6 x 1.3 = 9.1 mm.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afabf47 elementor-widget elementor-widget-heading\" data-id=\"afabf47\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">INSERTION INTO THE BROTH<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b212758 elementor-widget elementor-widget-text-editor\" data-id=\"b212758\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Before immersing the sheath in a bath of molten metal, it must be preheated for 5 minutes on the surface of the furnace or molten metal. Subsequently submerge the sheath into the molten metal slowly (up to 5 cm for 10-20 seconds).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ddb3ab9 elementor-widget elementor-widget-heading\" data-id=\"ddb3ab9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">REMOVING FROM THE OVEN<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49d6e87 elementor-widget elementor-widget-text-editor\" data-id=\"49d6e87\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>After taking the sleeve out of the molten metal bath, hang it in a special, marked place in your factory. It should never drip, be placed on the ground directly or put in contact with a cold wall (metallic or non-metallic). They must remove any excess metal or dirt each time they remove the cover from the bathroom, since the accumulation of metal can crack it.<\/p><p>The covers have excellent properties but misuse considerably shortens their life.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2ea6f6 elementor-widget elementor-widget-heading\" data-id=\"f2ea6f6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">CLEANING THE COVER<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25b3876 elementor-widget elementor-widget-text-editor\" data-id=\"25b3876\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>To remove excess metal and dirt from the sleeves, scrape them longitudinally with a steel spatula while the sleeve is still hot. Never hit the sleeve.<br \/>surface or metals stuck to the sleeve with a hammer as this may damage or break the sleeve.<\/p><p>Never leave the casing inserted in the aluminum when it solidifies or when loading with ingots, scrap or stock as the casing can be damaged. The mechanical stress produced by these actions at high temperatures can cause breaks or cracks that considerably shorten the life of this product.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b666d83 elementor-widget elementor-widget-heading\" data-id=\"b666d83\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">CAUTION !<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-675f78cc elementor-widget elementor-widget-text-editor\" data-id=\"675f78cc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><strong>\u00a0DRY THE COVER BEFORE USE<\/strong><br \/>Do not insert the wet sheath into molten metal, molten metal could splash and this is very dangerous as you could get burned or start a fire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-55639cf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"55639cf\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-69db33c1\" data-id=\"69db33c1\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-45784517 elementor-widget elementor-widget-heading\" data-id=\"45784517\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-large\">DO YOU NEED ADVICE?<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15db3d7f elementor-widget elementor-widget-text-editor\" data-id=\"15db3d7f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"font-weight: 400; text-align: center;\">\u00a0Send us your inquiry and our technical department will contact you as soon as possible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-497f7d94 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"497f7d94\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"mailto:consultas@srcsl.com\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">SEND INQUIRY<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>How to keep temperature sensors in optimal condition for aluminum casting? Maintaining sensors in aluminum casting is a key task for ensuring their proper performance. Temperature is one of the primary variables in an aluminum casting process. It is necessary to monitor and maintain control [\u2026]<\/p>","protected":false},"author":2,"featured_media":2526,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[51],"tags":[53,52],"class_list":["post-1135","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-noticias","tag-fundicion-aluminio","tag-mantenimiento-sondas-aluminio"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Mantenimiento de sensores de temperatura en fundici\u00f3n no f\u00e9rrica<\/title>\n<meta name=\"description\" content=\"\u00bfSabes c\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura? Consigue nuestra guia de mantenimiento de sensores en fundici\u00f3n de aluminio\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mantenimiento de sensores de temperatura en fundici\u00f3n no f\u00e9rrica\" \/>\n<meta property=\"og:description\" content=\"\u00bfSabes c\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura? Consigue nuestra guia de mantenimiento de sensores en fundici\u00f3n de aluminio\" \/>\n<meta property=\"og:url\" content=\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/\" \/>\n<meta property=\"og:site_name\" content=\"SRC - Sistemas de regulaci\u00f3n y control\" \/>\n<meta property=\"article:published_time\" content=\"2016-03-01T10:45:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-09T13:36:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alex Saldias\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/\"},\"author\":{\"name\":\"Alex Saldias\",\"@id\":\"https:\/\/srcsl.com\/en\/#\/schema\/person\/bf70ff95dcb341bdeccdfb73f1c23926\"},\"headline\":\"\u00bfC\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura para fundici\u00f3n de aluminio?\",\"datePublished\":\"2016-03-01T10:45:57+00:00\",\"dateModified\":\"2026-02-09T13:36:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/\"},\"wordCount\":1110,\"publisher\":{\"@id\":\"https:\/\/srcsl.com\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg\",\"keywords\":[\"Fundici\u00f3n aluminio\",\"Mantenimiento sondas aluminio\"],\"articleSection\":[\"Noticias\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/\",\"url\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/\",\"name\":\"Mantenimiento de sensores de temperatura en fundici\u00f3n no f\u00e9rrica\",\"isPartOf\":{\"@id\":\"https:\/\/srcsl.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg\",\"datePublished\":\"2016-03-01T10:45:57+00:00\",\"dateModified\":\"2026-02-09T13:36:50+00:00\",\"description\":\"\u00bfSabes c\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura? Consigue nuestra guia de mantenimiento de sensores en fundici\u00f3n de aluminio\",\"breadcrumb\":{\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage\",\"url\":\"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg\",\"contentUrl\":\"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg\",\"width\":1920,\"height\":1280,\"caption\":\"fundas aluminio\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/srcsl.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u00bfC\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura para fundici\u00f3n de aluminio?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/srcsl.com\/en\/#website\",\"url\":\"https:\/\/srcsl.com\/en\/\",\"name\":\"SRC - Sistemas de regulaci\u00f3n y control\",\"description\":\"Especialistas en regulaci\u00f3n y control de temperatura\",\"publisher\":{\"@id\":\"https:\/\/srcsl.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/srcsl.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/srcsl.com\/en\/#organization\",\"name\":\"SRC - Sistemas de regulaci\u00f3n y control\",\"url\":\"https:\/\/srcsl.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/srcsl.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/srcsl.com\/wp-content\/uploads\/2019\/01\/favicon.png\",\"contentUrl\":\"https:\/\/srcsl.com\/wp-content\/uploads\/2019\/01\/favicon.png\",\"width\":162,\"height\":154,\"caption\":\"SRC - Sistemas de regulaci\u00f3n y control\"},\"image\":{\"@id\":\"https:\/\/srcsl.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/srcsl.com\/en\/#\/schema\/person\/bf70ff95dcb341bdeccdfb73f1c23926\",\"name\":\"Alex Saldias\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/srcsl.com\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/35ee0e5dd6a2a672635597da650818d4b99006099477e3852690cd04cc7e6d02?s=96&d=blank&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/35ee0e5dd6a2a672635597da650818d4b99006099477e3852690cd04cc7e6d02?s=96&d=blank&r=g\",\"caption\":\"Alex Saldias\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Maintenance of temperature sensors in non-ferrous casting","description":"Do you know how to keep temperature sensors in optimal condition? Get our maintenance guide for cast aluminum sensors","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/","og_locale":"en_US","og_type":"article","og_title":"Mantenimiento de sensores de temperatura en fundici\u00f3n no f\u00e9rrica","og_description":"\u00bfSabes c\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura? Consigue nuestra guia de mantenimiento de sensores en fundici\u00f3n de aluminio","og_url":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/","og_site_name":"SRC - Sistemas de regulaci\u00f3n y control","article_published_time":"2016-03-01T10:45:57+00:00","article_modified_time":"2026-02-09T13:36:50+00:00","og_image":[{"width":1920,"height":1280,"url":"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg","type":"image\/jpeg"}],"author":"Alex Saldias","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#article","isPartOf":{"@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/"},"author":{"name":"Alex Saldias","@id":"https:\/\/srcsl.com\/en\/#\/schema\/person\/bf70ff95dcb341bdeccdfb73f1c23926"},"headline":"\u00bfC\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura para fundici\u00f3n de aluminio?","datePublished":"2016-03-01T10:45:57+00:00","dateModified":"2026-02-09T13:36:50+00:00","mainEntityOfPage":{"@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/"},"wordCount":1110,"publisher":{"@id":"https:\/\/srcsl.com\/en\/#organization"},"image":{"@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage"},"thumbnailUrl":"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg","keywords":["Fundici\u00f3n aluminio","Mantenimiento sondas aluminio"],"articleSection":["Noticias"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/","url":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/","name":"Maintenance of temperature sensors in non-ferrous casting","isPartOf":{"@id":"https:\/\/srcsl.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage"},"image":{"@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage"},"thumbnailUrl":"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg","datePublished":"2016-03-01T10:45:57+00:00","dateModified":"2026-02-09T13:36:50+00:00","description":"Do you know how to keep temperature sensors in optimal condition? Get our maintenance guide for cast aluminum sensors","breadcrumb":{"@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#primaryimage","url":"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg","contentUrl":"https:\/\/srcsl.com\/wp-content\/uploads\/2023\/06\/mix-fundas-aluminio-e1663593321222-scaled.jpg","width":1920,"height":1280,"caption":"fundas aluminio"},{"@type":"BreadcrumbList","@id":"https:\/\/srcsl.com\/en\/maintenance-of-sensors-in-non-ferrous-casting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/srcsl.com\/"},{"@type":"ListItem","position":2,"name":"\u00bfC\u00f3mo mantener en \u00f3ptimo estado los sensores de temperatura para fundici\u00f3n de aluminio?"}]},{"@type":"WebSite","@id":"https:\/\/srcsl.com\/en\/#website","url":"https:\/\/srcsl.com\/en\/","name":"SRC - Sistemas de regulaci\u00f3n y control","description":"Specialists in regulation and temperature control","publisher":{"@id":"https:\/\/srcsl.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/srcsl.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/srcsl.com\/en\/#organization","name":"SRC - Sistemas de regulaci\u00f3n y control","url":"https:\/\/srcsl.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/srcsl.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/srcsl.com\/wp-content\/uploads\/2019\/01\/favicon.png","contentUrl":"https:\/\/srcsl.com\/wp-content\/uploads\/2019\/01\/favicon.png","width":162,"height":154,"caption":"SRC - Sistemas de regulaci\u00f3n y control"},"image":{"@id":"https:\/\/srcsl.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/srcsl.com\/en\/#\/schema\/person\/bf70ff95dcb341bdeccdfb73f1c23926","name":"Alex Saldias","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/srcsl.com\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/35ee0e5dd6a2a672635597da650818d4b99006099477e3852690cd04cc7e6d02?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/35ee0e5dd6a2a672635597da650818d4b99006099477e3852690cd04cc7e6d02?s=96&d=blank&r=g","caption":"Alex Saldias"}}]}},"_links":{"self":[{"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/posts\/1135","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/comments?post=1135"}],"version-history":[{"count":164,"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/posts\/1135\/revisions"}],"predecessor-version":[{"id":16269,"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/posts\/1135\/revisions\/16269"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/media\/2526"}],"wp:attachment":[{"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/media?parent=1135"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/categories?post=1135"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/srcsl.com\/en\/wp-json\/wp\/v2\/tags?post=1135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}